| Model: |
HP-MX |
| Categories: |
Pressure Transmitter |
| Description: |
|
|
| Intrinsically safe pressure
transmitter for industrial use |
|
|
|
| |
|
Electrical Data |
|
Max. measuring range |
1…2000 bar |
|
Overload pressure |
6…1200 bar(depending on
the Max. measuring range) |
|
Burst pressure |
9…1500 bar(depending on
the Max. measuring range) |
|
Output signal |
4…20 mA |
|
Supply voltage |
9…27 V |
|
Response time |
<1 ms |
|
Accuracy |
≤0.50%,(optional ≤0.25%) |
|
Mechanical Data |
|
Housing |
Stainless steel |
|
Parts in contact with
the measuring medium |
Stainless steel |
|
Shock resistance |
1000 g |
|
Vibration resistance |
20 g |
|
Measuring medium
temperature |
-40℃…+85℃
|
|
Ambient temperature |
-40℃…+85℃ |
|
Storage temperature |
-40℃…+125℃ |
|
Protection |
IP65(special version up to IP69K) |
|
Connector |
M12×1; MVS/A; MVS/C; Cable * |
|
Pressure connection |
G 1/4 A, Form E; G1/4 B;G1/2 B; 1/4 NPT * |
|
Directive ATEX
Type of ignition protection |
II 2G Ex ia IIC T4
(IBExU 04 ATEX 1182) |
|
Underlying standards |
EN 50014, EN 50020 |
*Custom-made adjustments acc. to pressure connections and connecting options are possible. |
| [Back] |